1 Scope

Addition:
This Particular Standard applies to RADIOTHERAPY SIMULATORS:
- that use diagnostic X-RAY EQUIPMENT to simulate physically a RADIOTHERAPY RADIATION BEAM, so that the TREATMENT VOLUME to be subjected to IRRADIATION during RADIOTHERAPY can be localized, and the position and size of the RADIOTHERAPY RADIATION FIELD can be confirmed;
- intended exclusively for RADIOTHERAPY simulation as a prelude to intended RADIOTHERAPY, and not for any other purpose such as general diagnostic examinations;
- used within the environmental and electrical supply conditions SPECIFIED in the technical description;
- comprising the following parts:
  • - a system for producing an X-RAY BEAM, which simulates the geometry of the RADIOTHERAPY RADIATION BEAM;
  • - a system for producing images of the transmitted X-RAY BEAM, for example, either by RADIOGRAPHY or RADIOSCOPY;
  • - an assembly to control the size and position of the RADIATION BEAM and to delineate the intended treatment area;
  • - a mechanical structure that physically simulates the geometry and movements of the RADIOTHERAPY EQUIPMENT and supports the imaging system;
  • - a PATIENT SUPPORT system.


  • 1 Domaine d'application

    Complement:
    Cette Norme Particuliere s'applique aux SIMULATEURS DE RADIOTHERAPIE:
    - qui utilisent un EQUIPEMENT A RAYONNEMENT X de diagnostic pour simuler la geometrie d'un FAISCEAU DE RAYONNEMENT de RADIOTHERAPIE afin que le VOLUME TRAITE soumis a l'IRRADIATION pendant la RADIOTHERAPIE puisse etre localise et que la position et les dimensions du CHAMP DE RAYONNEMENT de RADIOTHERAPIE puissent etre confirmees;
    - utilises exclusivement pour une simulation de RADIOTHERAPIE preliminaire a un traitement de RADIOTHERAPIE determine, et non pour d'autres utilisations telles que les examens de diagnostic general;
    - utilises selon les conditions d'environnement et d'alimentation electrique SPECIFIEES dans la description technique;
    - comprenant les elements suivants:
    - un systeme produisant un FAISCEAU DE RAYONNEMENT X, qui simule les caracteristiques geometriques du FAISCEAU DE RAYONNEMENT de RADIOTHERAPIE;
    - un systeme produisant des images du FAISCEAU DE RAYONNEMENT X transmis, par exemple, par RADIOGRAPHIE ou par RADIOSCOPIE;
    - un dispositif qui permet de regler les dimensions et la positiondu FAISCEAU DE RAYONNEMENT, et de DELINEER la zone devant etre traitee;
    - une structure mecanique qui simule physiquement la geometrie et les mouvements de l'APPAREIL DE RADIOTHERAPIE et qui supporte ledispositif imageur;
    - un dispositif SUPPORT DU PATIENT.
    Note : This product is unavailable in Russia, Ukraine, Belarus
    Published : 12/05/2002

    History


    Related products

    CAN/CSA C22.2 NO. 601.2.15-92 (R01)
    Published Date: 09/14/2000
    Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Capacitor Discharge X-Ray Generators (Adopted IEC 601-2-15:1988)
    $14.1
    CAN/CSA C22.2 NO. 745-3-95 (R1999)
    Published Date: 01/19/2000
    Safety of Portable Battery-Operated Tools - Part 3: General Requirements (Bi-national standard, with UL 745-3)
    $17.4

    Best-Selling Products

    NEMA/MITA CSP 2-2021
    Published Date: 2021
    Lifecycle Best Practices Framework for Medical Imaging Devices
    $14.7
    NEMA/MITA DD P1-2019
    Published Date: 08/01/2019
    White Paper on Understanding the Limited Usefulness of Detector Dose Measurements in Modern Medical X-ray Imaging Equipment
    $24.6
    NEMA/MITA RMD P1-2019
    Published Date: 01/30/2019
    White Paper on Considerations for Remanufacturing of Medical Imaging Devices
    $14.7
    NEMA/MITA RSSTCD 1-2019
    Published Date: 2019
    White Paper on Radiation Safety Specification and Testing Comparison Document for Medical X-Ray Imaging Devices General Radiography and Fluoroscopy, and Interventional Fluoroscopy
    $28.8
    NEMA/MITA RSSTCD 2-2020
    Published Date: 2020
    White Paper on 21 CFR Subchapter J to IEC Comparison Table for Medical X-Ray Imaging Devices Mammography
    $30
    NEMA/MITA SAC 1-2020
    Published Date: 2020
    White Paper on Understanding Accountability in Medical Device Servicing
    $14.7